screwfix electric hob. You simply use a standard cooker circuit. screwfix electric hob

 
 You simply use a standard cooker circuitscrewfix electric hob  The oven is rated at 16 amp

4. Black PVC Sheathed Cable. £8. Order online at Screwfix. So we divide the 10kw, by 230 volts =43. The flex from the hob as 2 live and 2neutral for 2 or single phase. 5 hr flex is fine if its a gas one 1. Cooke & Lewis CLCER30A Ceramic Hob Black 60mm x 290mm (777FK) compare. 5KW electric hob. Flexible delivery available. #4. 4 Cooking Functions. Automatic switch-off timer and up to 9 adjustable power levels per zone. If you really want a 5 ring ceramic/induction hob, you will have to hire a Quartz fitter to make the cutout wider. 3500w for 16A input. 47 x 30 % =10. This stainless steel hob is compact and lightweight, and has variable independent heat control and power on the two separate cooking plates: 1500W and 750W. the issue I'm having is that I have 2 cables now ( one for oven and 1 for hob) the old cooker had 1 cable into a single connection plate. Both the old and new hob are rated at 5. (6mm2 T&E feed to switched spur, 2. Child Safety Lock Mechanism. Do they go any bigger and would it be feasible to fit. Is there a minimum distance required between the back of the electric oven and the copper gas pipes. 2 x Plate Sizes. So much easier to keep clean. so as i understand it, if I found a lower powered hob I could hard wire that in to the cooker switch? and plug the oven in to the 2 gang socket and keep the 30A? pugilist_specialist , Mar 1, 2016 #21Check all connected cables are clamped on their copper conductors ,not their insulation,at hob and wall plate. The oven is just plug in but the hob needs hard wiring. That isn't the process. 6A) Oven - 3. 590 mm. £4. Screwfix Community Forum. The connection units will be fine behind. £7. Safety Gas Cut-Out. I don't think so, the hob is currently gas and the oven electric just plugged in to a double socket at the back. Cooke & Lewis GASUIT4 Gas Hob Stainless Steel 83mm x 580mm. Repair Service Contact. Easy to clean. An uneven pan base that isn't in contact won't heat well with them - hence the ubiquitous 10kg pan shaped cast iron lumps with ground bases beloved by owners of. . e30mark, Jan 23, 2006. Hob: must have a minimum thickness of 30 mm. Turn off the 32amp MCB to check. Garry Ingham said:. Don't be tempted to use masses a small bead. Order Cooke & Lewis CLCER60a Ceramic Hob Black 52mm x 590mm at Screwfix. Buy Kitchen Appliances at Screwfix. Each of the ovens is 5. 0800 324 7818. The touch panel controls are not working to increase, lower or shut down the hob. Its cooking zones and controls are invisible until your fingertips bring them to life. It has starting getting small cracks in the worktop around the edge of the hob next to the ring I use the most. UK call centre ready for your call 24/7. I have B32 and want a single oven and induction hob. Looks wired correctly. 3/5. If it is 7000W, this would be 29A at 240V, so 4mm2 flex (which could theoretically handle about 32A) should be OK. Screwfix London Victoria. 2 products Sort by. 68a - 35. #5. . I've cabled up to a CCU in 6 mm cable for an electric hob. 5 thanks in advanceBush RL60SPH Electric Solid Plate Hob - Stainless Steel. I have a electric hob (input 5500W) which my electrician has connected to the cooker switch using a 6mm T+E cable. £240 for a complete new hob - £220 for just the replacement glass top - if you don't feel competent to replicate how it was connected it's an easy. I've recently bought a ceramic hob for my kitchen. Add to basket. Make sure that the socket you test it on is RCD protected. Wife's son as give me an induction hob he as had given, to install. 3/5. I don't even get to turn the hob on, as soon as i turn the isolator switch on with the hob connected it trips the RCD. kimble New Member. Zanussi ZHRN640K Ceramic Hob Black - 59cm. Why not put the cabinet in that the integrated oven will sit in then fit the oven. It goes straight down into the ground, underneath the kitchen floor tiles, over to the other side of the kitchen where it is hardwired in. Suitable for use on domestic stoves, furnace chimneys, industrial ovens and exhausts. HC9621FR Five zone ceramic hob. I have and electric cooker hardwired into a cooker point that is within 2m of the cooker - i also want to put and electric induction hob on the other side of the kitchen, i will but putting in a separate feed does this also have to have a cooker switch and does it need to be visible? Neither a cooker nor a hob need isolation. The hob can run on 6mm and even 2. com. 85 kg. 29 Inc Vat. 60 days free credit available. It doesn't trip every time I switch it on. Buy Electric Hobs at Screwfix. Cooke & Lewis CLCER30A Ceramic Hob Black 60mm x 290mm (777FK) Cooke & Lewis CLCER30A Ceramic Hob Black 60mm x 290mm. Total Product Weight. Having a switch on the wall doesn’t mean you can install an electric hob and oven, it might only be rated for supplying the clock and ignition on the gas cooker. Many thanks for your reply A tiny bead of clear sili, then wiped with a water and washing up liquid dipped finger or sponge will seal this. Induction hob / electric oven. I already have an electric oven and gas hob fitted. The question is this. The cooker is rated at 10. Having googled the wire type its some sort of flex cable. The oven is fitted with heavy duty 2. Bennysouth New Member. Neither have any cables attached, but both state 4mm cable on the connection points. Screwed Faceplate. If no flex is fitted ,likely to require hard wiring back to the CU, with local isolation, usually in adjacent cupboard or above worktop. - Switch 2: connected to 2x. Helps to prevent mould and mildew. Yes providing the replacement hob is of the same rating as the previous one. The problem is that our current integrated oven and built in hob are situated under a window, and a kitchen designer has told us we cannot have a new gas hob in the same place. #3. He told her that she will need to get an electrician to carry out the electrics. Buy any 10+ Save 10% - View Offer. I will investigate same sized electric hobs, hopefully, about 70 quid and 40 pound take out and fit. 6a = 24. Ceramic Hobs and Electric Ovens Installation. Conventional single electric oven with hard wired cable connection, twin grill and double-glazed door. Apple Pay accepted in store. Child Safety Lock Mechanism. Crabtree Capital 20A 1-Gang DP Hob Switch White (7483J) compare. £ 6. unphased, Feb 4, 2018. Product information. stateit, Jan 11, 2014. #3. Power indicator and automatic switch-off timer to control each zone. Those who increase the cable size to 10mm2 are unfamiliar with domestic cooker circuits and are wasting money; it wont achieve any benefit whatsoever. FREE next day delivery available, free collection in 1 minute. Brown, Blue & Green/Yellow Cores. The trouble is the old hob contained the junction box with the 6mm input from tail hangin out of the wall, it then has a beefy looking 13amp round cable going to the oven, which appears to be a "plug in" Euro style lead. 29 Inc Vat. could it be wrong MCB rating, faulty MCB? any advice much appreciated cheers, SamDepends on the type of clips/clamps they send with the hob then. The cooker switch is on the opposite wall to the hob so I couldn’t wire it there even if I wanted to. UK call centre ready for your call. London. Oven is only rated at 2. com. I have a Howdens kitchen that is in the process of being built, and there is an electric hob in the worktop which seems to only be installed by placing it into the worktop with sponge strips. kitfit1 Screwfix Select. Buy any 10+ Save 10% - View Offer. Requires 25mm Back Box. if I get a replacement hob for my cracked glass hob do I need to be careful what side the terminals are on?Hi all, planning to replace my electric ceramic hob for an induction one. 5mm cable, supplied from a 45A cooker switch, which is supplied via 6mm cable, protected by a 40A MCB in the CU. FREE next day delivery available, free collection in 1 minute. Should the product require repair please contact our repair service to arrange collection and repair. stateit Screwfix Select. com. Hob. ca. Product code: 401376. So for a new cooker circuit, will they install a double socket under the worktop to plug in the electric oven and electric hob, then a single fused switch above worktop to control both at the top like this?Chris Sanderson New Member. 6mm cable would give 32A (7. 9KW - new electrical oven is: 3. If it works with L1 and L2 together, with the marking of “25A” usually meaning per phase, it is going to give 50A on the neutral at full load. incoming valve is secure and that you have no. com. 00. Hi,. I feel like I should take the hob out and put some sort of tape/barrier round. Large Capacity Easy to Wire Terminals. £438. A user asks how easy it is to change an electric hob for another one at home. Discussion in 'Electricians' Talk' started by alex250, Aug 1, 2004. Control Type: Touch. #11. 7kw loads and. When I switch the hob back on at the fuse board, it's ok again, but trips at a random time, even when not in use. Should the product require repair please contact our repair service to arrange collection and repair. #8. Repair Service Contact. Choose options. 16th edition. I have checked the specification re your comment "must be a small hob" The Neff hobs have a power management menu. Mr Milliamp Member. Repair Service Action. Heat-Resistant up to 600°C. Delivery Next day available. The Sigma3 countertop depth is the standard 600 mm but the splashback thickness (approx 15 mm) clearly reduces the useable depth to less than the minimum 600 mm required by Neff. 8kw. All on a 40amp breaker or would it be best to de-rate down to. Now we take off the first 10 amps and then use 30% of the remainder so, 33. 4KW load, ideally I'd like to be able to have the 20Amp option to get the most out of it. ★★★★★ ★★★★★ ( 3 ) Product code: 10534. I intend to replace the single cooker by separate hob and grill/oven units with a total power consumption intended to be no more than the existing cooker. 3 phase supplyHi need bit of advice hope you guys can help recently bought a new Neff double oven,electric hob and microwave,all 16amp rating 240 volt. Click & Collect. mb New Member. White PVC Sheathed Cable. Now take the first 10A and 30% of the remainder =11. Pay your way. 2 kg. (62) From £349. I’m not an expert in this field but as it is would seem the back right hob ring will be very close to the gas supply pipe running down the wall. Page 1 of 1. View product Smeg SI4642D_BK 60cm Electric Hob - Black £. 85 kg. UK call centre ready for your call 24/7. Can't see from the spec but hob may be current limited. £72. But the hob draws 7. As others have said, look for the rating label on the hob, to use a 13A plug successfully it should not exceed 3. If you were to measure from the wall to the edge of the heat source, that would be more than 50mm. Also the supplied cable for the oven seems a bit lightweight to put into a connection plate. LAP 45A 2-Gang DP Cooker Switch & 13A DP Switched Socket Brushed Stainless Steel with Neon with Black Inserts (96499) Buy Cooker Switches at Screwfix. Skip to content. We’re replacing our gas oven with an electric oven but keeping the gas hob. hi all, I have fitted a new electric solid plate 4 ring hob and only 1 plate is working the plate with the red spot in the centre. Offer - 20% off this when you spend £1500+ on kitchen worktops, counters and doors. Most CERAMIC hobs are rated above 3kW and also require a 32A radial circuit. 8kw. 4. Customer complained she couldn't use the oven and hob at the same time as the fuse kept blowing. 3. 49 Inc Vat. richard Kenward New Member. 4KW 13Amp) as it is on its own 32Amp breaker and calculated with diversity (this was from online appliance advisor). Gas or Electric hob. 590 mm. Extract and recirculate kitchen steam and fumes. Flat or raised surfaces for cooking. It provides a protective barrier between the hob cabinet and the underside of the hob. My old kitchen had a stand-alone cooker running off a 32amp fuse (6mm) cable but new kitchen will have separate oven and induction hob. Perhaps I should persuade the my mother-in-law to get a decent electric hob ! Sam, Jun 16, 2006 #5. Home Forums > Screwfix Community Forum > Electricians' Talk > Electric hob. It's a new build, only 4 years old and has been fine. Currently have a built in electric oven which is hard wired in to the cooker switch & socket, and a gas hob with elec spark which is plugged in to a 2 gang socket in an adjacent cupboard. 4 Kw total load induction. Screwfix Community Forum. MGW Screwfix Select. Currently the oven is left disconnected. I'd be grateful for any help with the following. Products reviewed by the trade and home improvers. Can I wire L1 into the existing 20A feed into the existing feed that is being used, but wire the L2 into. Great deals on Electric Hobs. We've been using induction hobs since 2009. Child Safety Lock Mechanism. Plus - gas hobs rarely if ever go wrong, bar the igniters, but even these are infinitely more reliable than any type of electric hob. Both are RCD protected. Cooke & Lewis CLCER30A Ceramic Hob Black 60mm x 290mm (777FK) compare. Home Forums > Screwfix Community Forum > Electricians' Talk > Electric Oven and Electric Hob Discussion in ' Electricians' Talk ' started by RedRick , Nov 8, 2004 . Ask a question. You need to read it properly: The minimum distance between the supporting surface for the cooking equipment on the hob and the lowest part of the range hood must be not less than 55cm from electric cookers and 70cm from gas or mixed cookers. 8KW (Hotpoint DHS53X S Electric Double Built-in Oven) The Hob is a 4 ring 6. The pan base heats up. There's an existing dedicated cooker supply to a 32A breaker in the CU, via a 45A cooker isolation unit (the unit also has a. all 3 requie hard wiring. 49Inc Vat. Order Cooke & Lewis GASUIT4 Gas Hob Stainless Steel 83mm x 580mm at Screwfix. Cooke & Lewis CLGOGUIT4 Gas Glass Hob Black 94mm x 593mm. 1 2. 5KW and I have put it on a 32A breaker, with 6mm cable. 00. Cooke & Lewis CLCER30A 29cm Ceramic Hob - Black. The old chap over the road has asked asked for help replacing an electric hob. So :Hot plate hobs such as ceramic, traditional metal electric hobs, and one tonne lumps of hot cast iron (aka Aga) transfer heat to the pan by contact so the pan bases need to be flat. Bob Rathbone Screwfix Select. So we divide the 10kw, by 230 volts =43. 5R electric oven under the gas hob. Requires 46mm Back Box. It must only be a small induction hob to come with a plug though. 95 Inc Vat. Should the product require repair please contact our repair service to arrange collection and repair. However, the oven will still not fit because of a pipe coming down from the hob itself. It can move around slightly and I'm worried that with it not being secure it might affect the. I explained the situation. With this many stoves, ranges, ovens, and hoods to choose from, kitchen appliance shopping just got a lot easier. DIYDave. Order Cooke & Lewis CLCER60a Ceramic Hob Black 52mm x 590mm at Screwfix. UK call centre ready for your call 24/7. I was advised when I bought the hob that it would fine to put it on the same circuit as the cooker (max 2. Dimensions: (H)6cm x (W)60cm x (D)53cm. Discussion in 'Just Talk' started by koolpc, Aug 27, 2022. Buy online and collect in stores nationwide. Screwed Faceplate. Brown, Black, Blue, Grey & Green/Yellow Cores. com. Repair Service Contact. com. stateit, Jan 11, 2014. 6. Current oven is connected to a 16amp mcb at the fuse box,question is can I connect all 3 new units to this 16amp mcb,once theold oven is disconnected. 99 Inc Vat. Delivered by our approved supplier, Find out more. (a common problem on older oven and hob elements). It doesn't trip every time I switch it on. Home Tags > hob. 49 Inc Vat. Most are under 3 kW (approx rating for a 13A plug) 4 ring hob, probably not; unless it's a 2 ring 'domino hob' pulling less than 3 kW. 5kW for the oven and say 6. Screwfix customers rate this product 4. £164. the thicker one is the hob. Most sockets feeding things like dishwashers and washing machines are mounted inside an adjacent cupboad. oven spec: -cable type must be a minimum of ho5vv-f (pvc insulated and sheathed) 3 cores x 1. 2 x Ceramic Plates. Start at the MCB, then look at the isolation switch, the connection to the hob and any other strange junction that the LL or his skilled assistants may have introduced. Features 4 functions including grilling and plate warming. As for the oven supply, if it is within 2 metres, as the crow flies, from the oven switch, and the cable and breaker are big enough, yes, the two appliances may share the same supply in a domestic installation only. The regs allow a separate oven and hob to share the same supply and control unit provided that they are not more than 2 metres apart or from the control, that you apply diversity, that is you add the hob and oven current together, take the f1rst 10A of that total and add 30% of the remainder (add 5A if a socket is fitted to the cooker control, don't do. Double 13A sockets are only designed to handle 20amp. Screwfix Community Forum. The switch will act as an isolation switch for both. The oven is rated at 16 amp. Hans_25 Screwfix Select. Also the RCD will save you if the hob has a serious electrical fault. Free next day delivery available. My question is the. #26. Screwed Faceplate. I hope this the right thread. Fuse Rating 16 Amps. 68 per month*. get it done by a corgi reg installer. They are: 1) 220-240V 1N ~ H05V2V2-F 3G 2. Requires 25mm Back Box. The Scolmore one in your first link has two cable outlets. ABS Plastic. It could be fixed: 3. Timer. In the past we have always had freestanding cookers hardwired into the mains cable coming out of the wall. UK call centre ready for your call 24/7. Buy Hob Appliances at Screwfix. If I remember my 3-phase theory (that was a long time ago) current in neutral = Phasor sum of the 3 phase currents. Plus the layout of your new hob is even better. MGW Screwfix Select. I have a 6mm cable from my cu to a cooker connecter box via a 45 dp switch which protected by 30A fuse, I want to wiring in a 5. From £9. Inline Relays. Product Width. I usually paint the exposed chipboard edge with waterproof PVA (several coats), but you could use yacht varnish. #7. What is the standard way? Is it just a 6/10mm radial fed by a 32a MCB/RCBO, then onto a 45a DP switch above worktop, then onto a dual 45a plate outlet, then 2 feeds one to hob other to cooker?. I too am wanting to do this. Repair Service Action. Product Width. oven would go on a fused spur, the hob definantly would not, the hood should be a seperate consideration (on the kitchen ring etc). Screwfix customers rate this product 4. Single-Sided. 476-03-04 Every fixed or stationary appliance which may give rise to a hazard in normal use. I am exploring the option of swapping my neff gas hob for an electric induction one. Hi there. Hisense BI64211PB Built-in Single Multifunction pyrolytic Oven - Black. I purchased an electric built under double oven, the first couple wouldn't fit but now I have one with a slant at the back to allow for the gas pipe on the back of wall. Buy online and collect in store in as little as 1 minute. leaks. Please do not return to store. Yes, as pointed out above. Delivery. Yes, they would work perfectly well if plugged in on a 13A socket but the circuit would quickly overload when other appliances were plugged in. Below is the specifications for my old hob (which is now out of stock), underneath is a link to a new one i think will be a like for like swap, it is the same size and same amp, is there anything else i have overlooked? Model name/number CLIND1BK-C Colour Black Material Ceramic Fuel Electric Hob type Induction Number of burners 4. 97 Refurbished options available from £159. Having ploughed through loads of specification on AO. sally green Active Member. It's a new build, only 4 years old and has been fine. Discussion in 'Electricians' Talk' started by wrighty wrongy, May 2, 2016. Bosch PCP6A6B90 58cm Gas Hob - Black. Home Forums > Screwfix Community Forum > Electricians' Talk > New Electric hob.